So what about the house you have now?
I just have this perfect tank in my head that I want to build. We all have our visions, it's OK if they are different. I want a 5x5, 3x4, 3x6 maybe,...
60x60 is where I would like to be, and I can sacrifice rimless to do that. I do indeed like rimless, but going big I could be more practical. Euro...
That's really good to hear. Your last tank was kind of getto so nice to see you stepping it up. ;D
BKs are really nice, but they are not immune from physics. They too will fluctuate wildly with varying water levels. I loved mine... but for rock...
It will clean up. Nothing seriously toxic. Your foam head will come back.
Uhhh... holy crap! I'm with you now. Carry on. :)
The amps only mean the amount of current it is capable of putting out. And that is going to be at full voltage. As far as all the other controller...
You really do not need to calculate anything. PVC work is easy, and looking at flows is easy. If maintaining a reef tank is not over your head, then...
New PVC work will destroy the foam head. You will just have to wait. It's the glue and chemicals. Run some more carbon if you are not. No real need...
Bad... but good... yes, throttle the pump. Only move what you need to.
Everything you attach to a pump "throttles" it. There is not one single thing about throttling a pump. There is a point that you stop flow...
So you keep saying two drains, but you really main one big normal drain and one big emergency drain right? Not two separate herbie setups.?
Hummm... are you going to have two like this? What is the flow rate of a 2" pipe with a 1.25" pipe inside? The tee will not need to be a 2" line...
Been a long time since fluid flow class. I pretty much knew the obvious answer... but that was actually what I was looking for. Thanks for the...
Thats Matt. Sounds interesting. I'm interested what Greg sees.
I understand what a closed loop is. No need for a solenoid valve, if the power is off, so is the pump. What I am talking about is if you drain stand...
Hey, have you ever seen data on exactly how much friction is saved, using flex over rigid? I'm just curious. There still is a direction change and...
Try to stay away from barbed fittings... they neck down the I.D. significantly. I used threaded or slip and ran my line over the fitting.
I was thinking that, but it still sticks off the side and you would still have to have it in the sump. Just in some ad copy it seems they say they...